The following is the fault analysis of the electric heating tube heating type teppanyaki hibachi grill and the method of troubleshooting:
1. Press the power switch button to trip
Failure analysis: The power cord is damaged or the electric heating tube is damaged, resulting in a poor switch.
Solution: Check the power cord in detail and replace the power cord to eliminate the problem. If it still cannot be started, then check the electric heating tube to replace the electric heating tube, and finally check whether the switch is in good contact.
2. Japanese Smokeless Teppanyaki Table Equipment is not heated, the temperature is not enough
Failure analysis: The heating switch is defective or malfunctioning, or the temperature controller may be set incorrectly. After excluding these causes, see if it is a solid state relay failure or temperature control instrument damage. Finally, check the cause of the lack of phase of the power cord to see if the thermocouple is damaged.
Solution: The temperature is not enough to cause no heating. It is the key to replace the switch in time and then reset the temperature controller to check whether the power supply is burned out. Try to replace the thermocouple.
3. The fan of Electric Heating Japanese Teppanyaki Grill Table does not turn
Failure analysis: Bad fan switch is the main reason for inspection. Failure of the contactor may also cause the fan to not rotate. There is also a fan failure and power failure.
Solution: Replace the switch of the fan in time. If the contactor is damaged, it should be replaced immediately. Finally, update the fan and maintenance power supply.
4. Poor suction effect of Japanese Kitchen Teppanyaki Table Equipment (small air volume)
Failure analysis: Fan reversal is the main reason for the poor suction effect. The opening size of the air valve can also cause poor suction effect. After eliminating such causes, check whether there is foreign matter in the pipeline.
Solution: Change the phase of the power supply so that the fan is not reversed, adjust the air valve, and remove foreign objects in the pipeline.
5. The fan of Teppanyaki equipment has vibration or abnormal noise
Failure analysis: Foreign objects in the fan cause the abnormal noise of the fan, air leakage in the pipeline may also cause the fan to vibrate, and the fan has been aging for a long time, and the screws are loose.
Solution: Check the fan to remove foreign objects in the fan. Then check whether there is any damage in the pipeline and lock the fan fixing screw.
6. Large fume
Failure analysis: Dirty electrode plate of the fume purifier can also cause poor purification of the fume. The control module of the fume purifier is defective and the switch is defective.
Solution: Clean the motor board and replace the control module of the purifier, which can effectively solve the problem of large oil smoke and poor purification effect. The problem can be solved by replacing a good switch with large oil smoke.