Trouble Analysis and Elimination of Commercial Electric Disk Teppanyaki Grill Table

The following introduces the fault analysis and solutions of some electric disk Commercial Electric Teppanyaki Grill Table Machine:

 

1. Press the power switch button to trip

Failure Analysis: The damaged power cord leads to the damage of the electric heating tube, or the defective switch caused by the damage of the magnetic disk movement.

Solution: replace the power cord. If it is not possible, replace the heating tube, then you can follow the movement of the electric disk, and finally replace the broken switch.

 

2. Commercial Japanese Oval Hibachi Grill Table is not heated, the temperature is not enough

Failure analysis: The heating switch is bad, and the wrong setting of the temperature controller is also relatively common. Damage to the electric disk core may cause damage to the temperature controller, lack of phase of the power cord or damage to the thermocouple.

Solution: replace the switch, reset the temperature controller, check the power supply, replace the thermocouple and use it.

 

3. The fan of Mobile Smokeless Electric Hotel Teppanyaki Table does not turn

Failure analysis: Bad fan switch is that on the one hand, the failure of the contactor may cause the fan's faulty power supply to burn out.

Solution: replace the fan switch, replace the contactor and then replace the power supply under the replacement fan inspection.

 

4. Poor suction effect of Restaurant Teppanyaki Table equipment (small air volume or no wind)

Failure analysis: Reversing the fan may cause the air volume to decrease, and the opening of the air valve is too small. The presence of foreign objects in the pipe can also reduce the air volume.

Solution: Change the phase of the power supply to make the fan rotate normally, adjust the air valve, and remove foreign objects in the pipeline.

 

5. The fan has vibration or abnormal noise

Failure analysis: There are foreign objects in the fan that cause air leakage in the pipe, and the fixing screws of the fan are loose.

Solution: Remove foreign objects in the fan, check the pipeline, and tighten the screws.

 

6. Large fume

Failure analysis: The electrode plate of the fume purifier is too dirty, which causes the control module of the fume purifier to malfunction, resulting in a poor switch.

Solution: clean the electrode plate and replace the control module of the purifier, and replace the switch so that the fume can be completely absorbed, decomposed and discharged.

 

Trouble Analysis and Elimination of Commercial Electric Disk  Teppanyaki Grill Table